{"id":188676,"date":"2022-07-13T17:36:14","date_gmt":"2022-07-13T21:36:14","guid":{"rendered":"https:\/\/www.cati.com\/?p=188676"},"modified":"2022-07-13T17:36:14","modified_gmt":"2022-07-13T21:36:14","slug":"solidworks-flow-parameter-definition-transferred","status":"publish","type":"post","link":"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/","title":{"rendered":"SOLIDWORKS Flow Parameter Definition \u201cTRANSFERRED\u201d"},"content":{"rendered":"<p><a href=\"https:\/\/www.cati.com\/software\/solidworks-flow-simulation\/\" target=\"_blank\" rel=\"noopener\">SOLIDWORKS Flow Simulation<\/a> is a CFD tool that manages a variety of fluid flow analysis. Transient, Steady State, Thermal, Internal, External, and so on. When you combine various aspects of these analysis, like time dependency of a periodic load, and varying thermal constraints over the same period the project starts to become complicated. Do not worry, SOLIDWORKS Flow Simulation has you covered with the Flow Parameter Definition \u201cTransferred\u201d option.<\/p>\n<p>Let us look at the setup for the model. We have a series of periodic loads that are applied in real life over 24 hours. These loads vary in duration as well as temperature depending on the time at which the loading is applied, during that 24-hour window.<\/p>\n<p>For example, the load is periodic and turns on and off at a set time of 101 seconds on, and 6 seconds off. The load is applied at the first hour at 450 degrees C. For the second hour 50 degrees C, and 650 degrees C and so on.<\/p>\n<p>To create a manual time curve to define this series of events would be tedious. It is better to use the periodic application of the load and divide the overall 24 hours of real time run into multiple projects at given temperatures. We can divide the 24 hours into sections by transferring the boundary conditions as an initial condition in the subsequent run.<\/p>\n<p>To apply the periodic load, go to your heat source (or given boundary condition) and choose dependency. Dependency allows the user to adjust the loading via a time, goal, or parameter dependency. In this case we will use time and add the time curve to reflect 101 seconds on and 6 seconds off. Choosing periodic repeats this cycle.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" width=\"286\" height=\"477\" class=\"wp-image-188677 aligncenter\" src=\"https:\/\/www.cati.com\/wp-content\/uploads\/2022\/07\/graphical-user-interface-text-application-descr.png\" alt=\"Graphical user interface, text, application Description automatically generated\" srcset=\"\/wp-content\/uploads\/2022\/07\/graphical-user-interface-text-application-descr.png 286w, \/wp-content\/uploads\/2022\/07\/graphical-user-interface-text-application-descr-180x300.png 180w\" sizes=\"auto, (max-width: 286px) 100vw, 286px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" width=\"870\" height=\"534\" class=\"wp-image-188678 aligncenter\" src=\"https:\/\/www.cati.com\/wp-content\/uploads\/2022\/07\/graphical-user-interface-description-automaticall.png\" alt=\"Graphical user interface Description automatically generated\" srcset=\"\/wp-content\/uploads\/2022\/07\/graphical-user-interface-description-automaticall.png 870w, \/wp-content\/uploads\/2022\/07\/graphical-user-interface-description-automaticall-300x184.png 300w, \/wp-content\/uploads\/2022\/07\/graphical-user-interface-description-automaticall-768x471.png 768w\" sizes=\"auto, (max-width: 870px) 100vw, 870px\" \/><\/p>\n<p>In this case the heat source is 50 degrees C for 1 hour. Doing the overall 24 hours in a set of stages per hour allows the user to vary the temperature and reuse the periodic loading. Run the first hour project to completion. Clone the project naming it per the second loading condition. Edit and adjust the heat source (or boundary condition you want to vary) and change it to the new temperature.<\/p>\n<p>The next step is crucial to continue the run from the end of the first study. Edit the General Settings by right mouse button on the \u201cInput Data\u201d folder and choose General Settings.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" width=\"339\" height=\"331\" class=\"wp-image-188680 aligncenter\" src=\"https:\/\/www.cati.com\/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-description.png\" alt=\"Graphical user interface, application Description automatically generated\" srcset=\"\/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-description.png 339w, \/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-description-300x293.png 300w\" sizes=\"auto, (max-width: 339px) 100vw, 339px\" \/><\/p>\n<p>Go to the \u201cInitial and ambient conditions\u201d section<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" width=\"805\" height=\"581\" class=\"wp-image-188682 aligncenter\" src=\"https:\/\/www.cati.com\/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-description-1.png\" alt=\"Graphical user interface, application Description automatically generated\" srcset=\"\/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-description-1.png 805w, \/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-description-1-300x217.png 300w, \/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-description-1-768x554.png 768w\" sizes=\"auto, (max-width: 805px) 100vw, 805px\" \/><\/p>\n<p>At the pull down to the right of Parameter Definition choose \u201cTransferred\u201d<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" width=\"802\" height=\"579\" class=\"wp-image-188684 aligncenter\" src=\"https:\/\/www.cati.com\/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-table-desc.png\" alt=\"Graphical user interface, application, table Description automatically generated\" srcset=\"\/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-table-desc.png 802w, \/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-table-desc-300x217.png 300w, \/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-table-desc-768x554.png 768w\" sizes=\"auto, (max-width: 802px) 100vw, 802px\" \/><\/p>\n<p>Browse to the previous study. And choose OK<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" width=\"421\" height=\"519\" class=\"wp-image-188686 aligncenter\" src=\"https:\/\/www.cati.com\/wp-content\/uploads\/2022\/07\/graphical-user-interface-text-application-email.png\" alt=\"Graphical user interface, text, application, email Description automatically generated\" srcset=\"\/wp-content\/uploads\/2022\/07\/graphical-user-interface-text-application-email.png 421w, \/wp-content\/uploads\/2022\/07\/graphical-user-interface-text-application-email-243x300.png 243w\" sizes=\"auto, (max-width: 421px) 100vw, 421px\" \/><\/p>\n<p>This simple pull down allows the user to start the new subsequent study from the previous studies ending thermal, velocity, and pressure mapping. These two SOLIDWORKS Flow Simulation options, Periodic loading, and Transferred Flow parameters allow a user to setup and run a long duration set of studies with varying inputs over time.<\/p>\n<p>For more information reach out to your friendly CATI account manager. Check out the CATI <a href=\"https:\/\/www.youtube.com\/c\/CATICHANNEL\/featured\" target=\"_blank\" rel=\"noopener\">YouTube<\/a> page, and additional Simulation Blogs on the <a href=\"https:\/\/www.cati.com\/blog\/\" target=\"_blank\" rel=\"noopener\">CATI blog<\/a>.<\/p>\n<p><a id=\"post-188676-_Hlk519021756\"><\/a> <img loading=\"lazy\" decoding=\"async\" width=\"257\" height=\"257\" class=\"wp-image-188689\" src=\"https:\/\/www.cati.com\/wp-content\/uploads\/2022\/07\/a-person-looking-at-the-camera-description-genera.jpeg\" alt=\"A person looking at the camera Description generated with very high confidence\" srcset=\"\/wp-content\/uploads\/2022\/07\/a-person-looking-at-the-camera-description-genera.jpeg 257w, \/wp-content\/uploads\/2022\/07\/a-person-looking-at-the-camera-description-genera-150x150.jpeg 150w\" sizes=\"auto, (max-width: 257px) 100vw, 257px\" \/><\/p>\n<p>Robert Warren<br \/>\nSimulation Specialist, Elite Application Engineer<br \/>\n<a href=\"https:\/\/www.cati.com\" target=\"_blank\" rel=\"noopener\">Computer Aided Technology<\/a><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>SOLIDWORKS Flow Simulation is a CFD tool that manages a variety of fluid flow analysis. Transient, Steady State, Thermal, Internal, External, and so on. When you combine various aspects of these analysis, like time dependency of a periodic load, and varying thermal constraints over the same period the project starts to become complicated. Do not [&hellip;]<\/p>\n","protected":false},"author":12,"featured_media":188684,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[2271,2237,1165],"tags":[1584,119,1104],"class_list":["post-188676","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-design-validation","category-general-information","category-solidworks-flow-simulation","tag-how-to","tag-solidworks-flow-simulation","tag-robert-warren"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v22.5 (Yoast SEO v22.5) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>SOLIDWORKS Flow Parameter Definition \u201cTRANSFERRED\u201d<\/title>\n<meta name=\"description\" content=\"SOLIDWORKS Flow Simulation keeps many fluid flow analysis variables simple for you with the Flow Parameter Definition \u201cTransferred\u201d option.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SOLIDWORKS Flow Parameter Definition \u201cTRANSFERRED\u201d\" \/>\n<meta property=\"og:description\" content=\"SOLIDWORKS Flow Simulation keeps many fluid flow analysis variables simple for you with the Flow Parameter Definition \u201cTransferred\u201d option.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/\" \/>\n<meta property=\"og:site_name\" content=\"Computer Aided Technology\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ComputerAidedTechnology\" \/>\n<meta property=\"article:published_time\" content=\"2022-07-13T21:36:14+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.cati.com\/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-table-desc.png\" \/>\n\t<meta property=\"og:image:width\" content=\"802\" \/>\n\t<meta property=\"og:image:height\" content=\"579\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Robert Warren\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@CATISolidWorks\" \/>\n<meta name=\"twitter:site\" content=\"@CATISolidWorks\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Robert Warren\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/\"},\"author\":{\"name\":\"Robert Warren\",\"@id\":\"https:\/\/www.cati.com\/#\/schema\/person\/c75d27f00f87067b0fe5bf998b13b2b0\"},\"headline\":\"SOLIDWORKS Flow Parameter Definition \u201cTRANSFERRED\u201d\",\"datePublished\":\"2022-07-13T21:36:14+00:00\",\"dateModified\":\"2022-07-13T21:36:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/\"},\"wordCount\":503,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.cati.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/#primaryimage\"},\"thumbnailUrl\":\"\/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-table-desc.png\",\"keywords\":[\"How to\",\"SOLIDWORKS flow simulation\",\"Robert Warren\"],\"articleSection\":[\"Design Validation\",\"General Information\",\"SOLIDWORKS Flow Simulation\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/\",\"url\":\"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/\",\"name\":\"SOLIDWORKS Flow Parameter Definition \u201cTRANSFERRED\u201d\",\"isPartOf\":{\"@id\":\"https:\/\/www.cati.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/#primaryimage\"},\"thumbnailUrl\":\"\/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-table-desc.png\",\"datePublished\":\"2022-07-13T21:36:14+00:00\",\"dateModified\":\"2022-07-13T21:36:14+00:00\",\"description\":\"SOLIDWORKS Flow Simulation keeps many fluid flow analysis variables simple for you with the Flow Parameter Definition \u201cTransferred\u201d option.\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/#primaryimage\",\"url\":\"\/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-table-desc.png\",\"contentUrl\":\"\/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-table-desc.png\",\"width\":802,\"height\":579},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.cati.com\/#website\",\"url\":\"https:\/\/www.cati.com\/\",\"name\":\"Computer Aided Technology\",\"description\":\"Computer Aided Technology\",\"publisher\":{\"@id\":\"https:\/\/www.cati.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.cati.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.cati.com\/#organization\",\"name\":\"Computer Aided Technology\",\"url\":\"https:\/\/www.cati.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.cati.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/images.cati.com\/f00000000221344\/images.cati.com\/f00000000221344\/www.cati.com\/wp-content\/uploads\/2022\/03\/logo-official-horizontal-2021.png\",\"contentUrl\":\"https:\/\/images.cati.com\/f00000000221344\/images.cati.com\/f00000000221344\/www.cati.com\/wp-content\/uploads\/2022\/03\/logo-official-horizontal-2021.png\",\"width\":2155,\"height\":649,\"caption\":\"Computer Aided Technology\"},\"image\":{\"@id\":\"https:\/\/www.cati.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/ComputerAidedTechnology\",\"https:\/\/x.com\/CATISolidWorks\",\"https:\/\/www.linkedin.com\/company\/computer-aided-technology-inc\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.cati.com\/#\/schema\/person\/c75d27f00f87067b0fe5bf998b13b2b0\",\"name\":\"Robert Warren\",\"url\":\"https:\/\/www.cati.com\/blog\/author\/rwarren\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"SOLIDWORKS Flow Parameter Definition \u201cTRANSFERRED\u201d","description":"SOLIDWORKS Flow Simulation keeps many fluid flow analysis variables simple for you with the Flow Parameter Definition \u201cTransferred\u201d option.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/","og_locale":"en_US","og_type":"article","og_title":"SOLIDWORKS Flow Parameter Definition \u201cTRANSFERRED\u201d","og_description":"SOLIDWORKS Flow Simulation keeps many fluid flow analysis variables simple for you with the Flow Parameter Definition \u201cTransferred\u201d option.","og_url":"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/","og_site_name":"Computer Aided Technology","article_publisher":"https:\/\/www.facebook.com\/ComputerAidedTechnology","article_published_time":"2022-07-13T21:36:14+00:00","og_image":[{"width":802,"height":579,"url":"https:\/\/www.cati.com\/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-table-desc.png","type":"image\/png"}],"author":"Robert Warren","twitter_card":"summary_large_image","twitter_creator":"@CATISolidWorks","twitter_site":"@CATISolidWorks","twitter_misc":{"Written by":"Robert Warren","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/#article","isPartOf":{"@id":"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/"},"author":{"name":"Robert Warren","@id":"https:\/\/www.cati.com\/#\/schema\/person\/c75d27f00f87067b0fe5bf998b13b2b0"},"headline":"SOLIDWORKS Flow Parameter Definition \u201cTRANSFERRED\u201d","datePublished":"2022-07-13T21:36:14+00:00","dateModified":"2022-07-13T21:36:14+00:00","mainEntityOfPage":{"@id":"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/"},"wordCount":503,"commentCount":0,"publisher":{"@id":"https:\/\/www.cati.com\/#organization"},"image":{"@id":"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/#primaryimage"},"thumbnailUrl":"\/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-table-desc.png","keywords":["How to","SOLIDWORKS flow simulation","Robert Warren"],"articleSection":["Design Validation","General Information","SOLIDWORKS Flow Simulation"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/","url":"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/","name":"SOLIDWORKS Flow Parameter Definition \u201cTRANSFERRED\u201d","isPartOf":{"@id":"https:\/\/www.cati.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/#primaryimage"},"image":{"@id":"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/#primaryimage"},"thumbnailUrl":"\/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-table-desc.png","datePublished":"2022-07-13T21:36:14+00:00","dateModified":"2022-07-13T21:36:14+00:00","description":"SOLIDWORKS Flow Simulation keeps many fluid flow analysis variables simple for you with the Flow Parameter Definition \u201cTransferred\u201d option.","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.cati.com\/blog\/solidworks-flow-parameter-definition-transferred\/#primaryimage","url":"\/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-table-desc.png","contentUrl":"\/wp-content\/uploads\/2022\/07\/graphical-user-interface-application-table-desc.png","width":802,"height":579},{"@type":"WebSite","@id":"https:\/\/www.cati.com\/#website","url":"https:\/\/www.cati.com\/","name":"Computer Aided Technology","description":"Computer Aided Technology","publisher":{"@id":"https:\/\/www.cati.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.cati.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.cati.com\/#organization","name":"Computer Aided Technology","url":"https:\/\/www.cati.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.cati.com\/#\/schema\/logo\/image\/","url":"https:\/\/images.cati.com\/f00000000221344\/images.cati.com\/f00000000221344\/www.cati.com\/wp-content\/uploads\/2022\/03\/logo-official-horizontal-2021.png","contentUrl":"https:\/\/images.cati.com\/f00000000221344\/images.cati.com\/f00000000221344\/www.cati.com\/wp-content\/uploads\/2022\/03\/logo-official-horizontal-2021.png","width":2155,"height":649,"caption":"Computer Aided Technology"},"image":{"@id":"https:\/\/www.cati.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/ComputerAidedTechnology","https:\/\/x.com\/CATISolidWorks","https:\/\/www.linkedin.com\/company\/computer-aided-technology-inc\/"]},{"@type":"Person","@id":"https:\/\/www.cati.com\/#\/schema\/person\/c75d27f00f87067b0fe5bf998b13b2b0","name":"Robert Warren","url":"https:\/\/www.cati.com\/blog\/author\/rwarren\/"}]}},"_links":{"self":[{"href":"https:\/\/www.cati.com\/wp-json\/wp\/v2\/posts\/188676","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cati.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.cati.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.cati.com\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cati.com\/wp-json\/wp\/v2\/comments?post=188676"}],"version-history":[{"count":7,"href":"https:\/\/www.cati.com\/wp-json\/wp\/v2\/posts\/188676\/revisions"}],"predecessor-version":[{"id":188825,"href":"https:\/\/www.cati.com\/wp-json\/wp\/v2\/posts\/188676\/revisions\/188825"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.cati.com\/wp-json\/wp\/v2\/media\/188684"}],"wp:attachment":[{"href":"https:\/\/www.cati.com\/wp-json\/wp\/v2\/media?parent=188676"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.cati.com\/wp-json\/wp\/v2\/categories?post=188676"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.cati.com\/wp-json\/wp\/v2\/tags?post=188676"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}